Extreme Sensors for the Most Challenging Environments.     Check out our full line of accessories to complement your photoelectric systems.     Let us help you source those hard-to-find replacement parts from Europe — we will save you time and money.     Pantron Automation is proud to be the North American distributor for Fuchs Umwelttechnik, GmbH, manufacturer of high-quality fume and particulate extraction equipment.     If you have an application that’s causing problems, let us help you solve it with high-quality industrial sensors and controls that are designed to endure the worst conditions on the planet.     Are you interested in being a distributor for Pantron? Contact our Belmont office for details.     Need proximity sensors for extremely hot or cold environments? Check out the products offered by the German manufacturer, EGE Elektronik.    
Car wash automation Sawmill automation Machine automation Fume extraction Climate and environmental monitoring Sensors for robotics Sensors for food processing Welding sensors Sensors for pharmaceutical applications Sensors for doors and gates Sensors for wastewater applications Paper and pulp sensors
ICL-2100 amplifier
PANTRONICL-2100/24VDCDIN Rail

ICL-2100

2-channel multiplex infrared amplifier with analog output and PC configuration interface. The ICL-2100 is a two-channel multiplex amplifier for harsh industrial sensing environments. It supports manual or automatic operation, selectable light / dark switching, PNP switching outputs, an alarm output for power-limit indication, analog output, sensor control, test input, and a COM interface for PC configuration

Up to 35 m range2 channelsManual / automaticLight / dark selectable0 ... 10 V outputRS232

Key Features

  • Two-channel multiplex architecture for paired transmitter / receiver sensing paths.
  • Detection range up to 35 m in through-beam applications depending on optics pairing.
  • Manual or automatic transmit-power operation selectable.
  • Selectable light / dark switching behavior.
  • Two short-circuit-proof PNP switching outputs plus PNP alarm output.
  • 0 ... 10 V analog output for signal monitoring or setup support.
  • Test button with diagnostic function plus external test input.
  • COM interface (RS232) for configuration with a personal computer.
  • Primary / Secondary operation for coordinated system installations.
  • DIN rail mounting to EN 60715.

Best Fit Applications

  • Multi-beam or dual-channel machine monitoring in contamination-heavy automation areas.
  • Carwash, timber, paper, bulk-material, and process machinery where optics must tolerate dirt and spray.
  • Installations that benefit from analog signal feedback and alarm indication for maintenance planning.
  • Systems requiring PC-assisted setup, diagnostics, or primary / secondary networked amplifier behavior.

Technical Specifications

Channels 2
Operating voltage 24 V DC / ±20% / 3.6 W
Operating basis Modulated infrared light
Transmit frequency 4.0 kHz
Transmit power Manual / Automatic
Basic transmit level low1 / low2 / high1 / high2
Switching behaviour Light / Dark
Switching delay
Multiplex speed 10 ms
Primary / Secondary operation Yes
Reaction time 12 ms
Switching output 2x PNP, short circuit proof
Output rating 100 mA / 24 V DC
Alarm output PNP, short circuit proof
Alarm output rating 100 mA / 24 V DC
Test input max. 30 V DC / 2 mA
Operate voltage Low 5 V DC; High > 15 V DC
Analog output 0 ... 10 V DC
COM interface RS232
Housing material Polyamide
Protection class IP 00 (EN 60529)
Connection Phoenix Contact type MCV 1,5/8-G-3,81
Operating temperature -25 °C ... 50 °C
Dimensions 73 x 111 x 55 mm

Selectable Amplifier Modes

Selector Function Option A Option B
Amplifier mode Transmit power manual automatic
DIP selector Switching behavior light dark
Basic level Sensitivity family low1 / low2 high1 / high2
System mode Networking standalone primary / secondary

Compatible Sensor Pairs and Maximum Through-Beam Range

Transmitter family With receiver IRL-... With receiver IR-... Typical use note
IT-..., ITL-... 4 m 12 m Compact standard pairings
IT-...HP, ITH-... 7 m 19 m Higher power range extension
ITA-... 12 m 35 m Longest stated range for ICL-2100

Maximum through-beam ranges are shown for representative transmitter and receiver families. Real installation range depends on optics, contamination level, alignment, and mounting concept.

Ordering and Accessories

Connection style Order code
Plug (spring clamp terminals) ICL-2100/24VDC
Accessory Order code Catalog page
Protective enclosure PanBox 1x2 78
Power supply PSU-1000 PSU-1000S/95...265VAC 80
Communication cable CAB-COM-2 84
PC software WinICL 85

Device Layout and Wiring Notes

  • Connector X1 handles supply voltage, test input, primary / secondary, analog output, alarm output, and switching output.
  • Connector X2 is used for transmitter and receiver wiring.
  • Connector X3 provides a 24 V output and COM connection via RJ45.
  • Front status elements include a red / green status LED, green power LED, and two channel LEDs in yellow / red / green.
  • A front operator button and DIP switch bank are provided for setup and amplifier mode selection.

Related Products

Contact Us

Share a few details below and our team will respond with recommended options, pricing, and lead time.

We typically respond within one business day.