Extreme Sensors for the Most Challenging Environments.     Check out our full line of accessories to complement your photoelectric systems.     Let us help you source those hard-to-find replacement parts from Europe — we will save you time and money.     Pantron Automation is proud to be the North American distributor for Fuchs Umwelttechnik, GmbH, manufacturer of high-quality fume and particulate extraction equipment.     If you have an application that’s causing problems, let us help you solve it with high-quality industrial sensors and controls that are designed to endure the worst conditions on the planet.     Are you interested in being a distributor for Pantron? Contact our Belmont office for details.     Need proximity sensors for extremely hot or cold environments? Check out the products offered by the German manufacturer, EGE Elektronik.    
Car wash automation Sawmill automation Machine automation Fume extraction Climate and environmental monitoring Sensors for robotics Sensors for food processing Welding sensors Sensors for pharmaceutical applications Sensors for doors and gates Sensors for wastewater applications Paper and pulp sensors
ICL-8100 amplifier
PANTRONICL-8100/24VDCDIN Rail

ICL-8100

The ICL-8100 is an eight-channel multiplex amplifier for high-channel-count optical sensing systems in harsh industrial environments. It provides selectable manual or automatic operation, light / dark switching, eight PNP switching outputs, alarm output, analog output, primary / secondary capability, and RS232 communication for configuration and diagnostics.

Up to 35 m range8 channels34 ms multiplex speedPNP outputs0 ... 10 V outputRS232

Key Features

  • Eight-channel multiplex architecture for the largest ICL-series sensing groups shown in the catalog section.
  • Detection range up to 35 m in through-beam operation depending on sensor pairing.
  • Selectable manual or automatic transmit-power control.
  • Selectable light / dark switching behavior.
  • Eight short-circuit-proof PNP switching outputs plus PNP alarm output.
  • 0 ... 10 V analog output for diagnostics and setup assistance.
  • Primary / Secondary operation for coordinated multi-amplifier systems.
  • COM interface (RS232) for configuration with a personal computer.
  • DIN rail form factor for electrical cabinet integration.

Best Fit Applications

  • High-density optical monitoring zones that benefit from one central amplifier platform.
  • Harsh automation environments with contamination, washdown, or long-range through-beam requirements.
  • Multi-channel systems that need centralized diagnostics, analog feedback, and alarm monitoring.
  • Larger OEM or retrofit packages where primary / secondary networking simplifies architecture.

Technical Specifications

Channels 8
Operating voltage 24 V DC / ±20% / 3.6 W
Operating basis Modulated infrared light
Transmit frequency 4.0 kHz
Transmit power Manual / Automatic
Basic transmit level low1 / low2 / high1 / high2
Switching behaviour Light / Dark
Switching delay
Multiplex speed 34 ms
Primary / Secondary operation Yes
Reaction time 36 ms
Switching output 8x PNP, short circuit proof
Output rating 100 mA / 24 V DC
Alarm output PNP, short circuit proof
Alarm output rating 100 mA / 24 V DC
Test input max. 30 V DC / 2 mA
Operate voltage Low 5 V DC; High > 15 V DC
Analog output 0 ... 10 V DC
COM interface RS232
Housing material Polyamide
Protection class IP 00 (EN 60529)
Connection Phoenix Contact type MCV 1,5/8-G-3,81
Operating temperature -25 °C ... 50 °C
Dimensions 111 x 111 x 55 mm

Selectable Amplifier Modes

Selector Function Option A Option B
Amplifier mode Transmit power manual automatic
DIP selector Switching behavior light dark
Basic level Sensitivity family low1 / low2 high1 / high2
System mode Networking standalone primary / secondary

Use the manufacturer documentation for commissioning detail and full DIP-switch mapping.

Compatible Sensor Pairs and Maximum Through-Beam Range

Transmitter family With receiver IRL-... With receiver IR-... Typical use note
IT-..., ITL-... 4 m 12 m Standard compact optics
IT-...HP, ITH-... 7 m 19 m Higher power range extension
ITA-... 12 m 35 m Longest stated range for ICL-8100

Maximum through-beam ranges are shown for representative transmitter and receiver families. Real installation range depends on optics, contamination level, alignment, and mounting concept.

Ordering and Accessories

Connection style Order code
Plug (spring clamp terminals) ICL-8100/24VDC
Accessory Order code Catalog page
Protective enclosure PanBox 1x8 78
Power supply PSU-1000 PSU-1000S/95...265VAC 80
Communication cable CAB-COM-2 84
PC software WinICL 85

Device Layout and Wiring Notes

  • Connector X1 carries supply voltage, test input, primary / secondary, analog output, and alarm output.
  • Connector X2 carries switching outputs 1 through 8.
  • Connectors X4 and X5 wire transmitters 1-4 and 5-8 respectively.
  • Connectors X6 and X3 wire receivers 1-4 and 5-8 respectively.
  • Front status indicators include a red / green status LED, power LED with system-stop indication, and eight channel LEDs in yellow / red / green.
  • A front operator button, DIP switch bank, and RJ45 COM connector provide local setup and communication access.

Related Products