Extreme Sensors for the Most Challenging Environments.     Check out our full line of accessories to complement your photoelectric systems.     Let us help you source those hard-to-find replacement parts from Europe — we will save you time and money.     Pantron Automation is proud to be the North American distributor for Fuchs Umwelttechnik, GmbH, manufacturer of high-quality fume and particulate extraction equipment.     If you have an application that’s causing problems, let us help you solve it with high-quality industrial sensors and controls that are designed to endure the worst conditions on the planet.     Are you interested in being a distributor for Pantron? Contact our Belmont office for details.     Need proximity sensors for extremely hot or cold environments? Check out the products offered by the German manufacturer, EGE Elektronik.    
Car wash automation Sawmill automation Machine automation Fume extraction Climate and environmental monitoring Sensors for robotics Sensors for food processing Welding sensors Sensors for pharmaceutical applications Sensors for doors and gates Sensors for wastewater applications Paper and pulp sensors
ISM-1220S amplifier
PANTRONISM-1220S seriesDIN Rail

ISM-1220S

1-channel AC-powered infrared amplifier with manual / automatic operation and change-over relay output. The ISM-1220S is a single-channel ISM-series amplifier for long-range through-beam detection in contamination-heavy industrial environments. It combines selectable manual or automatic operation, selectable light / dark switching, two transmit frequencies, power-limit alarm outputs, and a change-over relay output in a DIN-rail package intended for applications that prefer AC supply power.

Up to 50 m rangeManual / automaticChange-over relay0 ... 10 s delay

Key Features

  • Detection range up to 50 m in through-beam use, depending on transmitter and receiver pairing.
  • Manual or automatic operation can be selected on the front DIP-switch.
  • Basic transmit level is 2-fold selectable.
  • Switching behaviour is selectable between light and dark mode.
  • Transmit frequency can be selected between 3.7 kHz and 4.3 kHz.
  • Relay output with change-over contacts for broader control integration.
  • Two normally-open semiconductor outputs indicate alarm / power-limit status and error conditions.
  • Includes test input, sensor control, and DIN-rail mounting to EN 60715.

Best Fit Applications

  • Retrofits and machine panels where AC operating voltage is preferred or already available.
  • Long-range optical detection in dusty, wet, or contamination-heavy environments.
  • Industrial doors, wash equipment, bulk-material systems, timber handling, and similar harsh-process applications.
  • Installations that need relay switching plus selectable response delay.

Compared with the lower-power 24 VDC single-channel variants, the ISM-1220S adds AC supply options, change-over relay output, and configurable switching delay.

Technical Specifications

Channels 1
Operating voltage See order table (24 V AC / 115 V AC / 230 V AC, ±10%, 4.8 VA)
Operating basis Modulated infrared light
Transmit frequency 3.7 kHz / 4.3 kHz
Transmit power Manual / Automatic
Basic transmit level Low / High
Switching behaviour Light / Dark
Switching delay 0 ... 10 s
Multiplex speed
Primary / Secondary operation
Reaction time 36 ms
Switching output Relay, change over
Output rating 5 A / 230 V AC (24 V DC)
Alarm output / Error output 2x semiconductor relay, normally open
Alarm / Error output rating 100 mA / 24 V DC
Test input 0 ... 30 V DC
Analog output
COM interface
Housing material NORYL, grey
Protection class IP20 (EN 60529)
Connection Screw terminals
Wire size 0.14 ... 2.5 mm²
Operating temperature -25 °C ... 50 °C
Dimensions 52.8 x 90 x 58.5 mm

Operating Modes and Configuration

Selector Function Option A Option B
1 Operation mode manual automatic
2 Basic transmit level high low
3 Switching behaviour light dark
4 Transmit frequency 3.7 kHz 4.3 kHz
5 Switching method delay pulse
6 Switching reaction on off

Compatible Sensor Pairs and Maximum Through-Beam Range

Transmitter family With receiver IRL-... With receiver IR-... Typical use note
IT-..., ITL-... 8 m 15 m Compact standard pairings
IT-...HP, ITH-... 10 m 20 m Higher-power range extension
ITA-... 20 m 50 m Longest stated range with ISM-1220S

Ordering and Accessories

Operating voltage Order code
230 V AC / ±10% / 4.8 VA ISM-1220S/230VAC
115 V AC / ±10% / 4.8 VA ISM-1220S/115VAC
24 V AC / ±10% / 4.8 VA ISM-1220S/24VAC
Accessory Order code Catalog page
Protective enclosure PanBox 1x1 78

Device Layout and Wiring Notes

  • Front indicators include power display, intensity display, output status, alarm display, and sensor error display LEDs.
  • Gain and delay / pulse timing are adjusted from the front panel potentiometers.
  • A front Test / Reset button supports system checks.
  • Connection diagram shows AC operating voltage, relay change-over output, alarm / error outputs, transmitter, receiver, and test input.

This model is intended for installations that need AC power input and a more conventional relay interface while keeping the optical performance of the ISM family.