Extreme Sensors for the Most Challenging Environments.     Check out our full line of accessories to complement your photoelectric systems.     Let us help you source those hard-to-find replacement parts from Europe — we will save you time and money.     Pantron Automation is proud to be the North American distributor for Fuchs Umwelttechnik, GmbH, manufacturer of high-quality fume and particulate extraction equipment.     If you have an application that’s causing problems, let us help you solve it with high-quality industrial sensors and controls that are designed to endure the worst conditions on the planet.     Are you interested in being a distributor for Pantron? Contact our Belmont office for details.     Need proximity sensors for extremely hot or cold environments? Check out the products offered by the German manufacturer, EGE Elektronik.    
Car wash automation Sawmill automation Machine automation Fume extraction Climate and environmental monitoring Sensors for robotics Sensors for food processing Welding sensors Sensors for pharmaceutical applications Sensors for doors and gates Sensors for wastewater applications Paper and pulp sensors
ICL-6100 amplifier
PANTRONICL-6100/24VDCDIN Rail

ICL-6100

The ICL-6100 is a six-channel multiplex amplifier designed for dense optical sensing installations in difficult industrial environments. It combines manual or automatic operation, selectable light / dark switching, six short-circuit-proof PNP outputs, alarm output, analog output, and PC configuration through an RS232 interface. Multiple devices may be linked together to create a virtual light grid.

34 ms multiplex speedPNP outputs0 ... 10 V outputRS232

Key Features

  • Six-channel multiplex control for larger multi-beam sensing systems.
  • Detection range up to 35 m in through-beam configurations depending on the optical pair.
  • Selectable manual or automatic transmit-power control.
  • Selectable light / dark switching behavior.
  • Six short-circuit-proof PNP switching outputs plus PNP alarm output.
  • 0 ... 10 V analog output for process visibility and commissioning support.
  • Primary / Secondary operation for coordinated multi-unit installations.
  • COM interface (RS232) for configuration with WinICL software.
  • DIN rail housing for panel integration to EN 60715.

Best Fit Applications

  • Larger machine zones that need several optical channels in one DIN rail amplifier.
  • Carwash, lumber, conveying, and process installations where dirt resistance and long range matter.
  • Systems requiring centralized diagnostics, alarm indication, and software-based configuration.
  • Installations where multiple transmitters and receivers need coordinated multiplex operation.

Technical Specifications

Channels 6
Operating voltage 24 V DC / ±20% / 4.2 W
Operating basis Modulated infrared light
Transmit frequency 4.0 kHz
Transmit power Manual / Automatic
Basic transmit level low1 / low2 / high1 / high2
Switching behaviour Light / Dark
Switching delay
Multiplex speed 34 ms
Primary / Secondary operation Yes
Reaction time 36 ms
Switching output 6x PNP, short circuit proof
Output rating 100 mA / 24 V DC
Alarm output PNP, short circuit proof
Alarm output rating 100 mA / 24 V DC
Test input max. 30 V DC / 2 mA
Operate voltage Low 5 V DC; High > 15 V DC
Analog output 0 ... 10 V DC
COM interface RS232
Housing material Polyamide
Protection class IP 00 (EN 60529)
Connection Phoenix Contact type MCV 1,5/6-G-3,81
Operating temperature -25 °C ... 50 °C
Dimensions 111 x 111 x 55 mm

Selectable Amplifier Modes

Selector Function Option A Option B
Amplifier mode Transmit power manual automatic
DIP selector Switching behavior light dark
Basic level Sensitivity family low1 / low2 high1 / high2
System mode Networking standalone primary / secondary

Compatible Sensor Pairs and Maximum Through-Beam Range

Transmitter family With receiver IRL-... With receiver IR-... Typical use note
IT-..., ITL-... 5 m 15 m Standard channel pairing
IT-...HP, ITH-... 8 m 20 m Higher power range extension
ITA-... 14 m 35 m Longest stated range for ICL-6100

Maximum through-beam ranges are shown for representative transmitter and receiver families. Real installation range depends on optics, contamination level, alignment, and mounting concept.

Ordering and Accessories

Connection style Order code
Plug (spring clamp terminals) ICL-6100/24VDC
Accessory Order code Catalog page
Protective enclosure PanBox 1x8 79
Power supply PSU-1000 PSU-1000S/95...265VAC 80
Communication cable CAB-COM-2 84
PC software WinICL 85

Device Layout and Wiring Notes

  • Connector X1 handles supply voltage, test input, primary / secondary, analog output, and alarm output.
  • Connector X2 carries switching outputs 1 through 6.
  • Connectors X4 and X5 wire transmitters 1-3 and 4-6 respectively.
  • Connectors X6 and X3 wire receivers 1-3 and 4-6 respectively.
  • Front-panel indicators include red / green status, green power with yellow system-stop indication, and six channel LEDs in yellow / red / green.
  • An operator button, DIP switch bank, and RJ45 COM connector support setup and diagnostics.

Related Products

Contact Us

Share a few details below and our team will respond with recommended options, pricing, and lead time.

We typically respond within one business day.